TRUEMAX SC200/200 series hoists comparison | ||||
Model | General low speed domestic motor & reducer |
VFD Low speed domestic motor & reducerr |
VFD Low speed imported motor & reducer |
|
Item | Unit | Parameter, index and instruction | ||
Rated load capacity | kg | 2000 | 2000 | 2000 |
Max installation height | m | 150 | 450 | 450 |
Lifting speed | m/min | 34 | 0~40 | 0~40 |
Motor working system | kw | 3×11 | 3×11 | 2×11 |
Motor working system | S3-25% | S3-25% | S1-100% | |
Speed radio of reducer | 1:16 | 1:16 | 1:23 | |
Inverter power | kw | - | 45 | 37 |
Up going acceleration time | s | - | 5 | 5 |
Down going acceleration time | s | - | 2 | 2 |
Motor rated current | A | 70.5 | 70.5 | 72.4 |
Startup instantaneous current | A | 350~490 | <70 | <58 |
Full load up going current | A | <76 | <70 | <58 |
Full load down going current | A | >48 | <1.5 | <1.5 |
Ratio of energy saving | - | >30.5% | >32% | |
Service life for wearable parts(estimated value) | ||||
Small pinion | Month | 6 | 12 | 12 |
Small roller wheel | Month | 6 | 12 | 12 |
Brake piece | Month | 6 | 18 | 18 |
Rack | Year | 2 | 4 | 4 |
Power consumption per month(estimated value) | ||||
Ammeter(8h×30day) | kw*h | 11712 | 8160 | 7960 |
Percentage of power consumption | 100% | 69.70% | 68% |